Structural design for vernacular architecture

Structural truth for vernacular buildings.

Assess and strengthen adobe, traditional timber, and stone masonry — with heritage damage factors, EN 1998-3 knowledge levels, and a defensible, code-referenced report an engineer can cite.

Windows desktopfully offline30-day free trial at launch

VERIFIED150+TESTS PASS

17 verification cases — hand calculations and published worked examples, pinned as regression tests. This stamp is earned, not drawn.

17
Verification cases
5
vs. published worked examples
6
Real defects caught & fixed
193
Automated tests, every build

Built for conservation engineers

General FEM packages have no adobe, no palm or athel timber, no damage factors, no ICOMOS logic. VernaStruct is a specialised member checker for traditional construction — fast, code-referenced, and honest about its assumptions.

Roofs

Round-timber joists and steel or bundled-trunk main beams, with the traditional earth-layer dead-load stack built in.

NDS 2018 · EN 1995-1-1 · AISC 360 §F2 · EN 1993-1-1

Walls

Adobe compression, shear with the hard code cap, H/t limits, wind and seismic in-plane checks, overturning.

SBC 902-2024 §806 · EN 1996-1-1

Columns

Compression-plus-bending interaction with slenderness, including a tapered palm-trunk preset — a section no other tool has.

NDS 2018 Ch. 15 · §3.7.2 tapered

Foundations

Strip and pad bearing with Meyerhof effective width, elastic settlement against the masonry serviceability criterion.

SBC 303-2018 · Skempton & MacDonald

Damage factors

Observed deterioration derates capacity — 1.00 sound to 0.50 severe — stated explicitly in every report, per element.

ICOMOS ISCARSAH · ASCE 41 aligned

Knowledge levels

How well you know the material is a second, orthogonal axis: KL1–KL3 confidence factors divide strengths before design.

EN 1998-3 §3.3 · CF 1.35 / 1.20 / 1.00

Real output, real numbers

From an anonymised assessment scenario — a damaged adobe house under seismic load — exported directly by the app, unedited.

DEMO — 45 seconds, silent: a full building checked, one honest FAIL, and the quantitative strengthening advice that follows. Built from real exported output.
VernaStruct report: project information and design summary table with D/C ratios
01 / 02 — Full-building design summary: every element, its governing check, D/C ratio and verdict.
VernaStruct report: wall design results — slenderness, axial, in-plane shear, overturning, heritage clauses
04 / 08 — Wall detail: slenderness, axial, in-plane shear & overturning, with every heritage clause cited.

The desktop app, reimagined in glass.

The interface direction for the next generation of VernaStruct: the same four modules and honest verdicts, floating in one calm surface. Numbers below are a real run — a 3 m mud-brick wall, moderate damage, KL2.

VernaStruct 7.2 — Heritage Structural Designer ● Licensed

Wall — Mud Brick (Handmade)

SBC 902-2024 §806 · damage 0.75 · KL2 CF 1.20
Height3.00 m
Thickness0.50 m
Axial dead0.50 t/m
Lateral sourceseismic Fp
Checks
Axial compression
0.42 PASS
H/t slenderness · limit 6
6.00 PASS
In-plane shear
0.31 PASS
Overturning FS · req 1.5
1.72 PASS
§806.7 applied: adobe shear capacity capped at 82.7 kPa — the code cap governs over the tested material value. Stated in the report.

Static concept mock — the production app runs on the verified engine shown in the numbers above.

Verified before it is sold

Nobody should trust structural software on faith. Every check is pinned against an independent hand calculation or a published worked example — and the full manual ships with the product.

Selected cases — full record in the Verification Manual
CaseCross-check sourceModuleResult
VC-13Structville, published EN 1995-1-1 worked examplecodes.ec5PASS
VC-14Structville, published EN 1996-1-1 worked examplecodes.ec6PASS
VC-15Swedish Wood, official Eurocode 5 textbook (Vol. 3)codes.ec5PASS — caught a real defect
VC-16Published NTC / Circolare 2019 assessment practicecodes.knowledgePASS
VC-17Published EN 1993-1-1 section tables (HEB200, Class 1)codes.ec3PASS
  1. Adobe out-of-plane bending overstated 1000× — N·m read as kN·m; unconservative. Fixed, pinned. VC-03
  2. Pad-footing pressure overstated 1000× — the pad branch had never been numerically exercised. VC-04
  3. Governing utilization omitted creep — long-term deflection missing from the reported maximum. VC-05
  4. Column stability factor shortcut — CP forced to 1.0 for stocky columns, ~4% unconservative. VC-06
  5. EC5 shear crack factor missing — §6.1.7 kcr = 0.67 omitted; shear understated 1.49×. Caught by the Swedish Wood textbook example. VC-15
  6. Default beam section modulus digit-swap — HEA200 Wx 368.5 vs published 388.6 cm³; caught by the library-wide Wx ≈ 2Ix/h consistency test. Library integrity

Browse the full Verification Manual →

Built by a heritage structural engineer.
Verified like one.

VernaStruct is entering closed beta for conservation engineers — free beta access and a free v1.0 license for structured feedback.