Assess and strengthen adobe, traditional timber, and stone masonry — with heritage damage factors, EN 1998-3 knowledge levels, and a defensible, code-referenced report an engineer can cite.
17 verification cases — hand calculations and published worked examples, pinned as regression tests. This stamp is earned, not drawn.
General FEM packages have no adobe, no palm or athel timber, no damage factors, no ICOMOS logic. VernaStruct is a specialised member checker for traditional construction — fast, code-referenced, and honest about its assumptions.
Round-timber joists and steel or bundled-trunk main beams, with the traditional earth-layer dead-load stack built in.
Adobe compression, shear with the hard code cap, H/t limits, wind and seismic in-plane checks, overturning.
Compression-plus-bending interaction with slenderness, including a tapered palm-trunk preset — a section no other tool has.
Strip and pad bearing with Meyerhof effective width, elastic settlement against the masonry serviceability criterion.
Observed deterioration derates capacity — 1.00 sound to 0.50 severe — stated explicitly in every report, per element.
How well you know the material is a second, orthogonal axis: KL1–KL3 confidence factors divide strengths before design.
From an anonymised assessment scenario — a damaged adobe house under seismic load — exported directly by the app, unedited.


The interface direction for the next generation of VernaStruct: the same four modules and honest verdicts, floating in one calm surface. Numbers below are a real run — a 3 m mud-brick wall, moderate damage, KL2.
Static concept mock — the production app runs on the verified engine shown in the numbers above.
Nobody should trust structural software on faith. Every check is pinned against an independent hand calculation or a published worked example — and the full manual ships with the product.
| Case | Cross-check source | Module | Result |
|---|---|---|---|
| VC-13 | Structville, published EN 1995-1-1 worked example | codes.ec5 | PASS |
| VC-14 | Structville, published EN 1996-1-1 worked example | codes.ec6 | PASS |
| VC-15 | Swedish Wood, official Eurocode 5 textbook (Vol. 3) | codes.ec5 | PASS — caught a real defect |
| VC-16 | Published NTC / Circolare 2019 assessment practice | codes.knowledge | PASS |
| VC-17 | Published EN 1993-1-1 section tables (HEB200, Class 1) | codes.ec3 | PASS |
VernaStruct is entering closed beta for conservation engineers — free beta access and a free v1.0 license for structured feedback.
Request a beta invite